1.
Rev. Col. Bras. Cir ; 40(3): 186-190, maio-jun. 2013. tab
Article in Portuguese | LILACS | ID: lil-680931

ABSTRACT

OBJETIVO: estudar retrospectivamente os resultados obtidos com a implantação de cateteres totalmente implantáveis em pacientes submetidos à quimioterapia. MÉTODOS: foram colocados 815 cateteres totalmente implantáveis em 793 pacientes submetidos ao regime de quimioterapia preferencialmente utilizando-se a veia cefálica direita. Foram avaliadas as complicações precoces e tardias. RESULTADOS: a análise retrospectiva mostrou duração média dos cateteres de 339 dias. Em 733 (90%) cateteres não se observou nenhuma complicação. Entre as complicações precoces observamos um pneumotórax, um mau posicionamento de cateter, uma punção arterial, um sangramento, um hemotórax e hemomediastino e seis hematomas na loja de implantação. Entre as complicações tardias, ocorreram 35 infecções relacionadas ao cateter, dez infecções no sítio cirúrgico, seis obstruções e 20 tromboses. Foram retirados 236 cateteres, 35 devido às complicações e 201 por final de tratamento. CONCLUSÃO: os cateteres totalmente implantáveis para quimioterapia são meios seguros para a administração de substâncias, em vista do baixo número de complicações observadas neste estudo.


OBJECTIVE: To retrospectively study the results obtained with the implementation of totally implantable catheters in patients undergoing chemotherapy. METHODS: 815 totally implantable catheters placed in 793 patients undergoing chemotherapy regimen, preferably using the right cephalic vein. We evaluated early and late complications. RESULTS: The retrospective analysis showed an average duration of 339 days of the catheters. In 733 (90%) catheters there was no observe complication. Among early complications we observed one pneumothorax, one bad positioning of the catheter, one arterial puncture, one bleeding, one hemothorax and hemomediastinum and six hematomas in the implantation site. As for late complications, there were 35 catheter-related infections ten, infections in the surgical site, six obstructions and 20 thromboses. We removed 236 catheters, 35 due to complications and 201 by the end of treatment. CONCLUSION: totally implantable catheters for chemotherapy are a safe means for the administration of substances, in view of the low number of complications observed in this study.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Child , Female , Humans , Male , Middle Aged , Young Adult , Antineoplastic Agents/administration & dosage , Catheters, Indwelling , Central Venous Catheters , Neoplasms/drug therapy , Catheters, Indwelling/adverse effects , Central Venous Catheters/adverse effects , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL